Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 137
Filter
1.
Nat Commun ; 15(1): 1584, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38383565

ABSTRACT

Astrocytes, a type of glial cell in the central nervous system (CNS), adopt diverse states in response to injury that are influenced by their location relative to the insult. Here, we describe a platform for spatially resolved, single-cell transcriptomics and proteomics, called tDISCO (tissue-digital microfluidic isolation of single cells for -Omics). We use tDISCO alongside two high-throughput platforms for spatial (Visium) and single-cell transcriptomics (10X Chromium) to examine the heterogeneity of the astrocyte response to a cortical ischemic stroke in male mice. We show that integration of Visium and 10X Chromium datasets infers two astrocyte populations, proximal or distal to the injury site, while tDISCO determines the spatial boundaries and molecular profiles that define these populations. We find that proximal astrocytes show differences in lipid shuttling, with enriched expression of Apoe and Fabp5. Our datasets provide a resource for understanding the roles of astrocytes in stroke and showcase the utility of tDISCO for hypothesis-driven, spatially resolved single-cell experiments.


Subject(s)
Astrocytes , Stroke , Mice , Animals , Male , Astrocytes/metabolism , Central Nervous System/metabolism , Stroke/genetics , Stroke/metabolism , Gene Expression Profiling , Chromium/metabolism
3.
Lab Chip ; 24(1): 63-73, 2023 12 20.
Article in English | MEDLINE | ID: mdl-37987330

ABSTRACT

There is great enthusiasm for using loop-mediated isothermal amplification (LAMP) in point-of-care nucleic acid amplification tests (POC NAATs), as an alternative to PCR. While isothermal amplification techniques like LAMP eliminate the need for rapid temperature cycling in a portable format, these systems are still plagued by requirements for dedicated optical detection apparatus for analysis and manual off-chip sample processing. Here, we developed a new microfluidic system for LAMP-based POC NAATs to address these limitations. The new system combines digital microfluidics (DMF) with distance-based detection (DBD) for direct signal readout. This is the first report of the use of (i) LAMP or (ii) DMF with DBD - thus, we describe a number of characterization steps taken to determine optimal combinations of reagents, materials, and processes for reliable operation. For example, DBD was found to be quite sensitive to background signals from low molecular weight LAMP products; thus, a Capto™ adhere bead-based clean-up procedure was developed to isolate the desirable high-molecular-weight products for analysis. The new method was validated by application to detection of SARS-CoV-2 in saliva. The method was able to distinguish between saliva containing no virus, saliva containing a low viral load (104 genome copies per mL), and saliva containing a high viral load (108 copies per mL), all in an automated system that does not require detection apparatus for analysis. We propose that the combination of DMF with distance-based detection may be a powerful one for implementing a variety of POC NAATs or for other applications in the future.


Subject(s)
Microfluidics , Nucleic Acids , Nucleic Acid Amplification Techniques , Polymerase Chain Reaction , Point-of-Care Systems , Point-of-Care Testing , Molecular Diagnostic Techniques/methods
4.
Vaccine ; 2023 Oct 10.
Article in English | MEDLINE | ID: mdl-37827968

ABSTRACT

On November 18-19, 2019, the Immunity of Canadians and Risk of Epidemics (iCARE) Network convened a workshop in Toronto, Ontario, Canada. The objectives of the workshop were to raise the profile of sero-epidemiology in Canada, discuss best practice and methodological innovations, and strategize on the future direction of sero-epidemiology work in Canada. In this conference report, we describe the presentations and discussions from the workshop, and comment on the impact of the COVID-19 pandemic on serosurveillance initiatives, both in Canada and abroad.

5.
J Proteome Res ; 22(10): 3242-3253, 2023 Oct 06.
Article in English | MEDLINE | ID: mdl-37651704

ABSTRACT

Proteome profiles of precious tissue samples have great clinical potential for accelerating disease biomarker discovery and promoting novel strategies for early diagnosis and treatment. However, tiny clinical tissue samples are often difficult to handle and analyze with conventional proteomic methods. Automated digital microfluidic (DMF) workflows facilitate the manipulation of size-limited tissue samples. Here, we report the assessment of a DMF microproteomics workflow enabled by a photocleavable surfactant for proteomic analysis of minute tissue samples. The surfactant 4-hexylphenylazosulfonate (Azo) was found to facilitate fast droplet movement on DMF and enhance the proteomics analysis. Comparisons of Azo and n-Dodecyl ß-d-maltoside (DDM) using small samples of HeLa digest standards and MCF-7 cell digests revealed distinct differences at the peptide level despite similar results at the protein level. The DMF microproteomics workflow was applied for the sample preparation of ∼3 µg biopsies from murine brain tissue. A total of 1969 proteins were identified in three samples, including established neural biomarkers and proteins related to synaptic signaling. Going forward, we propose that the Azo-enabled DMF workflow has the potential to advance the practical clinical application of DMF for the analysis of size-limited tissue samples.

6.
Cell Rep Methods ; 3(6): 100511, 2023 06 26.
Article in English | MEDLINE | ID: mdl-37426761

ABSTRACT

The identification of tumor-specific antigens (TSAs) is critical for developing effective cancer immunotherapies. Mass spectrometry (MS)-based immunopeptidomics has emerged as a powerful tool for identifying TSAs as physical molecules. However, current immunopeptidomics platforms face challenges in measuring low-abundance TSAs in a precise, sensitive, and reproducible manner from small needle-tissue biopsies (<1 mg). Inspired by recent advances in single-cell proteomics, microfluidics technology offers a promising solution to these limitations by providing improved isolation of human leukocyte antigen (HLA)-associated peptides with higher sensitivity. In this context, we highlight the challenges in sample preparation and the rationale for developing microfluidics technology in immunopeptidomics. Additionally, we provide an overview of promising microfluidic methods, including microchip pillar arrays, valved-based systems, droplet microfluidics, and digital microfluidics, and discuss the latest research on their application in MS-based immunopeptidomics and single-cell proteomics.


Subject(s)
Microfluidics , Neoplasms , Humans , Mass Spectrometry/methods , Histocompatibility Antigens Class I , HLA Antigens , Antigens, Neoplasm
7.
ACS Nano ; 17(6): 5894-5904, 2023 Mar 28.
Article in English | MEDLINE | ID: mdl-36912818

ABSTRACT

Steering micromotors is important for using them in practical applications and as model systems for active matter. This functionality often requires magnetic materials in the micromotor, taxis behavior of the micromotor, or the use of specifically designed physical boundaries. Here, we develop an optoelectronic strategy that steers micromotors with programmable light patterns. In this strategy, light illumination turns hydrogenated amorphous silicon conductive, generating local electric field maxima at the edge of the light pattern that attracts micromotors via positive dielectrophoresis. As an example, metallo-dielectric Janus microspheres that self-propelled under alternating current electric fields were steered by static light patterns along customized paths and through complex microstructures. Their long-term directionality was also rectified by ratchet-shaped light patterns. Furthermore, dynamic light patterns that varied in space and time enabled more advanced motion controls such as multiple motion modes, parallel control of multiple micromotors, and the collection and transport of motor swarms. This optoelectronic steering strategy is highly versatile and compatible with a variety of micromotors, and thus it possesses the potential for their programmable control in complex environments.

8.
Lab Chip ; 23(7): 1955, 2023 Mar 28.
Article in English | MEDLINE | ID: mdl-36938970

ABSTRACT

Correction for 'Virtual microwells for digital microfluidic reagent dispensing and cell culture' by Irwin A. Eydelnant et al., Lab Chip, 2012, 12, 750-757, https://doi.org/10.1039/C2LC21004E.

9.
Anal Chem ; 95(14): 5858-5866, 2023 04 11.
Article in English | MEDLINE | ID: mdl-36996326

ABSTRACT

Toxicity testing is currently undergoing a paradigm shift from examining apical end points such as death, to monitoring sub-lethal toxicity in vivo. In vivo nuclear magnetic resonance (NMR) spectroscopy is a key platform in this endeavor. A proof-of-principle study is presented which directly interfaces NMR with digital microfluidics (DMF). DMF is a "lab on a chip" method allowing for the movement, mixing, splitting, and dispensing of µL-sized droplets. The goal is for DMF to supply oxygenated water to keep the organisms alive while NMR detects metabolomic changes. Here, both vertical and horizontal NMR coil configurations are compared. While a horizontal configuration is ideal for DMF, NMR performance was found to be sub-par and instead, a vertical-optimized single-sided stripline showed most promise. In this configuration, three organisms were monitored in vivo using 1H-13C 2D NMR. Without support from DMF droplet exchange, the organisms quickly showed signs of anoxic stress; however, with droplet exchange, this was completely suppressed. The results demonstrate that DMF can be used to maintain living organisms and holds potential for automated exposures in future. However, due to numerous limitations of vertically orientated DMF, along with space limitations in standard bore NMR spectrometers, we recommend future development be performed using a horizontal (MRI style) magnet which would eliminate practically all the drawbacks identified here.


Subject(s)
Magnetic Resonance Imaging , Microfluidics , Magnetic Resonance Spectroscopy/methods , Metabolomics/methods , Lab-On-A-Chip Devices
10.
Chem Sci ; 14(11): 2887-2900, 2023 Mar 15.
Article in English | MEDLINE | ID: mdl-36937585

ABSTRACT

Highly sensitive and reproducible analysis of samples containing low amounts of protein is restricted by sample loss and the introduction of contaminants during processing. Here, we report an All-in-One digital microfluidic (DMF) pipeline for proteomic sample reduction, alkylation, digestion, isotopic labeling and analysis. The system features end-to-end automation, with integrated thermal control for digestion, optimized droplet additives for sample manipulation and analysis, and an automated interface to liquid chromatography with tandem mass spectrometry (HPLC-MS/MS). Dimethyl labeling was integrated into the pipeline to allow for relative quantification of the trace samples at the nanogram level, and the new pipeline was applied to evaluating cancer cell lines and cancer tissue samples. Several known proteins (including HSP90AB1, HSPB1, LDHA, ENO1, PGK1, KRT18, and AKR1C2) and pathways were observed between model breast cancer cell lines related to hormone response, cell metabolism, and cell morphology. Furthermore, differentially quantified proteins (such as PGS2, UGDH, ASPN, LUM, COEA1, and PRELP) were found in comparisons of healthy and cancer breast tissues, suggesting potential utility of the All-in-One pipeline for the emerging application of proteomic cancer sub-typing. In sum, the All-in-One pipeline represents a powerful new tool for automated proteome processing and analysis, with the potential to be useful for evaluating mass-limited samples for a wide range of applications.

11.
J Proteome Res ; 22(4): 1298-1308, 2023 04 07.
Article in English | MEDLINE | ID: mdl-36892105

ABSTRACT

Single-cell proteomics is emerging as an important subfield in the proteomics and mass spectrometry communities, with potential to reshape our understanding of cell development, cell differentiation, disease diagnosis, and the development of new therapies. Compared with significant advancements in the "hardware" that is used in single-cell proteomics, there has been little work comparing the effects of using different "software" packages to analyze single-cell proteomics datasets. To this end, seven popular proteomics programs were compared here, applying them to search three single-cell proteomics datasets generated by three different platforms. The results suggest that MSGF+, MSFragger, and Proteome Discoverer are generally more efficient in maximizing protein identifications, that MaxQuant is better suited for the identification of low-abundance proteins, that MSFragger is superior in elucidating peptide modifications, and that Mascot and X!Tandem are better for analyzing long peptides. Furthermore, an experiment with different loading amounts was carried out to investigate changes in identification results and to explore areas in which single-cell proteomics data analysis may be improved in the future. We propose that this comparative study may provide insight for experts and beginners alike operating in the emerging subfield of single-cell proteomics.


Subject(s)
Proteomics , Tandem Mass Spectrometry , Proteomics/methods , Tandem Mass Spectrometry/methods , Search Engine/methods , Software , Proteome/analysis , Databases, Protein
12.
Lab Chip ; 23(5): 816-817, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-36809551
13.
ACS Appl Mater Interfaces ; 15(5): 6326-6337, 2023 Feb 08.
Article in English | MEDLINE | ID: mdl-36696478

ABSTRACT

Fouling at liquid-solid interfaces is a pernicious problem for a wide range of applications, including those that are implemented by digital microfluidics (DMF). There are several strategies that have been used to combat surface fouling in DMF, the most common being inclusion of amphiphilic surfactant additives in the droplets to be manipulated. Initial studies relied on Pluronic additives, and more recently, Tetronic additives have been used, which has allowed manipulation of complex samples like serum and whole blood. Here, we report our evaluation of 19 different Pluronic and Tetronic additives, with attempts to determine (1) the difference in antifouling performance between the two families, (2) the structural similarities that predict exceptional antifouling performance, and (3) the mechanism of the antifouling behavior. Our analysis shows that both Pluronic and Tetronic additives with modest molar mass, poly(propylene oxide) (PPO) ≥50 units, poly(ethylene oxide) (PEO) mass percentage ≤50%, and hydrophilic-lipophilic balance (HLB) ca. 13-15 allow for exceptional antifouling performance in DMF. The most promising candidates, P104, P105, and T904, were able to support continuous movement of droplets of serum for more than 2 h, a result (for devices operating in air) previously thought to be out of reach for this technique. Additional results generated using device longevity assays, intrinsic fluorescence measurements, dynamic light scattering, asymmetric flow field flow fractionation, supercritical angle fluorescence microscopy, atomic force microscopy, and quartz crystal microbalance measurements suggest that the best-performing surfactants are more likely to operate by forming a protective layer at the liquid-solid interface than by complexation with proteins. We propose that these results and their implications are an important step forward for the growing community of users of this technique, which may provide guidance in selecting surfactants for manipulating biological matrices for a wide range of applications.


Subject(s)
Biofouling , Poloxamer , Humans , Poloxamer/chemistry , Surface-Active Agents , Microfluidics , Biofouling/prevention & control , Polyethylene Glycols/chemistry
14.
SLAS Technol ; 28(1): 2-15, 2023 02.
Article in English | MEDLINE | ID: mdl-36323389

ABSTRACT

Bacteria are widely studied in various research areas, including synthetic biology, sequencing and diagnostic testing. Protocols involving bacteria are often multistep, cumbersome and require access to a long list of instruments to perform experiments. In order to streamline these processes, the fluid handling technique digital microfluidics (DMF) has provided a miniaturized platform to perform various steps of bacterial protocols from sample preparation to analysis. DMF devices can be paired/interfaced with instrumentation such as microscopes, plate readers, and incubators, demonstrating their versatility with existing research tools. Alternatively, DMF instruments can be integrated into all-in-one packages with on-chip magnetic separation for sample preparation, heating/cooling modules to perform assay steps and cameras for absorbance and/or fluorescence measurements. This perspective outlines the beneficial features DMF offers to bacterial protocols, highlights limitations of current work and proposes future directions for this tool's expansion in the field.


Subject(s)
Bacteria , Microfluidics , Microfluidics/methods , Lab-On-A-Chip Devices
15.
Rev Sci Instrum ; 93(11): 113707, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-36461515

ABSTRACT

Supercritical angle fluorescence (SAF) microscopy is a novel imaging tool based on the use of distance-dependent fluorophore emission patterns to provide accurate locations of fluorophores relative to a surface. This technique has been extensively used to construct accurate cellular images and to detect surface phenomena in a static environment. However, the capability of SAF microscopy in monitoring dynamic surface phenomena and changes in millisecond intervals is underexplored in the literature. Here, we report on a hardware add-on for a conventional inverted microscope coupled with a post-processing Python module that extends the capability of SAF microscopy to monitor dynamic surface adsorption in sub-second intervals, thereby greatly expanding the potential of this tool to study surface interactions, such as surface fouling and competitive surface adhesion. The Python module enables researchers to automatically extract SAF profiles from each image. We first assessed the performance of the system by probing the specific binding of biotin-fluorescein conjugates to a neutravidin-coated cover glass in the presence of non-binding fluorescein. The SAF emission was observed to increase with the quantity of bound fluorophore on the cover glass. However, a high concentration of unbound fluorophore also contributed to overall SAF emission, leading to over-estimation in surface-bound fluorescence. To expand the applications of SAF in monitoring surface phenomena, we monitored the non-specific surface adsorption of BSA and non-ionic surfactants on a Teflon-AF surface. Solution mixtures of bovine serum albumin (BSA) and nine Pluronic/Tetronic surfactants were exposed to a Teflon-AF surface. No significant BSA adsorption was observed in all BSA-surfactant solution mixtures with negligible SAF intensity. Finally, we monitored the adsorption dynamics of BSA onto the Teflon-AF surface and observed rapid BSA adsorption on Teflon-AF surface within 10 s of addition. The adsorption rate constant (ka) and half-life of BSA adsorption on Teflon-AF were determined to be 0.419 ± 0.004 s-1 and 1.65 ± 0.016 s, respectively, using a pseudo-first-order adsorption equation.


Subject(s)
Fluorescent Dyes , Surface-Active Agents , Adsorption , Microscopy, Fluorescence , Fluorescein
16.
PLoS One ; 17(12): e0278749, 2022.
Article in English | MEDLINE | ID: mdl-36542608

ABSTRACT

The Democratic Republic of the Congo (DRC) has a high measles incidence despite elimination efforts and has yet to introduce rubella vaccine. We evaluated the performance of a prototype rapid digital microfluidics powered (DMF) enzyme-linked immunoassay (ELISA) assessing measles and rubella infection, by testing for immunoglobulin M (IgM), and immunity from natural infection or vaccine, by testing immunoglobulin G (IgG), in outbreak settings. Field evaluations were conducted during September 2017, in Kinshasa province, DRC. Blood specimens were collected during an outbreak investigation of suspected measles cases and tested for measles and rubella IgM and IgG using the DMF-ELISA in the field. Simultaneously, a household serosurvey for measles and rubella IgG was conducted in a recently confirmed measles outbreak area. DMF-ELISA results were compared with reference ELISA results tested at DRC's National Public Health Laboratory and the US Centers for Disease Control and Prevention. Of 157 suspected measles cases, rubella IgM was detected in 54% while measles IgM was detected in 13%. Measles IgG-positive cases were higher among vaccinated persons (87%) than unvaccinated persons (72%). In the recent measles outbreak area, measles IgG seroprevalence was 93% overall, while rubella seroprevalence was lower for children (77%) than women (98%). Compared with reference ELISA, DMF-ELISA sensitivity and specificity were 82% and 78% for measles IgG; 88% and 89% for measles IgM; 85% and 85% for rubella IgG; and 81% and 83% for rubella IgM, respectively. Rubella infection was detected in more than half of persons meeting the suspected measles case definition during a presumed measles outbreak, suggesting substantial unrecognized rubella incidence, and highlighting the need for rubella vaccine introduction into the national schedule. The performance of the DMF-ELISA suggested that this technology can be used to develop rapid diagnostic tests for measles and rubella.


Subject(s)
Measles , Rubella , Child , Humans , Female , Democratic Republic of the Congo/epidemiology , Seroepidemiologic Studies , Microfluidics , Antibodies, Viral , Rubella/diagnosis , Rubella/epidemiology , Rubella/prevention & control , Measles/diagnosis , Measles/epidemiology , Measles/prevention & control , Rubella Vaccine , Immunoglobulin M , Immunoglobulin G , Immunoenzyme Techniques , Disease Outbreaks
17.
Sci Transl Med ; 14(666): eabm1732, 2022 10 12.
Article in English | MEDLINE | ID: mdl-36223447

ABSTRACT

Diagnostics and drug delivery technologies engineered for low-resource settings aim to meet their technical design specifications using strategies that are compatible with limited equipment, infrastructure, and operator training. Despite many preclinical successes, very few of these devices have been translated to the clinic. Here, we identify factors that contribute to the clinical success of diagnostics and drug delivery systems for low-resource settings, including the need to engage key stakeholders at an early stage, and provide recommendations for the clinical translation of future medical technologies.


Subject(s)
Drug Delivery Systems
18.
Chem Soc Rev ; 51(22): 9203-9242, 2022 Nov 14.
Article in English | MEDLINE | ID: mdl-36285556

ABSTRACT

The rapid development of micromanipulation technologies has opened exciting new opportunities for the actuation, selection and assembly of a variety of non-biological and biological nano/micro-objects for applications ranging from microfabrication, cell analysis, tissue engineering, biochemical sensing, to nano/micro-machines. To date, a variety of precise, flexible and high-throughput manipulation techniques have been developed based on different physical fields. Among them, optoelectronic tweezers (OET) is a state-of-art technique that combines light stimuli with electric field together by leveraging the photoconductive effect of semiconductor materials. Herein, the behavior of micro-objects can be directly controlled by inducing the change of electric fields on demand in an optical manner. Relying on this light-induced electrokinetic effect, OET offers tremendous advantages in micromanipulation such as programmability, flexibility, versatility, high-throughput and ease of integration with other characterization systems, thus showing impressive performance compared to those of many other manipulation techniques. A lot of research on OET have been reported in recent years and the technology has developed rapidly in various fields of science and engineering. This work provides a comprehensive review of the OET technology, including its working mechanisms, experimental setups, applications in non-biological and biological scenarios, technology commercialization and future perspectives.


Subject(s)
Micromanipulation , Semiconductors , Micromanipulation/methods , Electricity , Optical Tweezers
19.
Lab Chip ; 22(9): 1748-1763, 2022 05 03.
Article in English | MEDLINE | ID: mdl-35357372

ABSTRACT

This paper introduces a digital microfluidic (DMF) platform for portable, automated, and integrated Zika viral RNA extraction and amplification. The platform features reconfigurable DMF cartridges offering a closed, humidified environment for sample processing at elevated temperatures, as well as programmable control instrumentation with a novel thermal cycling unit regulated using a proportional integral derivative (PID) feedback loop. The system operates on 12 V DC power, which can be supplied by rechargeable battery packs for remote testing. The DMF system was optimized for an RNA processing pipeline consisting of the following steps: 1) magnetic-bead based RNA extraction from lysed plasma samples, 2) RNA clean-up, and 3) integrated, isothermal amplification of Zika RNA. The DMF pipeline was coupled to a paper-based, colorimetric cell-free protein expression assay for amplified Zika RNA mediated by toehold switch-based sensors. Blinded laboratory evaluation of Zika RNA spiked in human plasma yielded a sensitivity and specificity of 100% and 75% respectively. The platform was then transported to Recife, Brazil for evaluation with infectious Zika viruses, which were detected at the 100 PFU mL-1 level from a 5 µL sample (equivalent to an RT-qPCR cycle threshold value of 32.0), demonstrating its potential as a sample processing platform for miniaturized diagnostic testing.


Subject(s)
Zika Virus Infection , Zika Virus , Humans , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques , RNA , RNA, Viral/analysis , RNA, Viral/genetics , Real-Time Polymerase Chain Reaction , Sensitivity and Specificity , Specimen Handling , Zika Virus/genetics , Zika Virus Infection/diagnosis
20.
Environ Sci Technol Lett ; 9(7): 638-644, 2022 Jul 12.
Article in English | MEDLINE | ID: mdl-37552744

ABSTRACT

Wastewater surveillance has rapidly emerged as an early warning tool to track COVID-19. However, the early warning measurement of new SARS-CoV-2 variants of concern (VOCs) in wastewaters remains a major challenge. We herein report a rapid analytical strategy for quantitative measurement of VOCs, which couples nested polymerase chain reaction and liquid chromatography-mass spectrometry (nPCR-LC-MS). This method showed a greater selectivity than the current allele-specific quantitative PCR (AS-qPCR) for tracking new VOC and allowed the detection of multiple signature mutations in a single measurement. By measuring the Omicron variant in wastewaters across nine Ontario wastewater treatment plants serving over a three million population, the nPCR-LC-MS method demonstrated a better quantification accuracy than next-generation sequencing (NGS), particularly at the early stage of community spreading of Omicron. This work addresses a major challenge for current SARS-CoV-2 wastewater surveillance by rapidly and accurately measuring VOCs in wastewaters for early warning.

SELECTION OF CITATIONS
SEARCH DETAIL
...